Safety Monitors - AS-i Quick Reference - 08/2014 6
2 SFM Safety Monitor
2.1 Password forgotten or lost
Read-out of the configuration from a monitor without password
1. Remove the AS-I cable from the monitor
2. Connect the ASiMon software PC to the monitor
3. In the ASi-Mon software under the menu item monitor >> Stop, click info the following
window
4. Press OK without entering anything here. The monitor will stop without having the
password
5. Now, go to the menu item monitor >> configuration protocol >> request and read-out
the protocol from the monitor
6. In line 8 of the protocol, you will find the code (B1B4 in this example)
7. Call EUCHNER and indicate this code; a replacement password can be ordered
8. Use the replacement password ONLY for changing of the password to a new one