Euchner CES-A-ABA-01B (Unicode) Manuale Utente Pagina 21

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 42
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 20
Operating Instructions Safety System CES-A-ABA-01/CES-A-ABA-01B
21
Pin assignment
Read head with connection cable
Technical Data
Parameter Value Unit
min. typ. max.
Housing material Fortron, reinforced thermoplastic, fully encapsulated
Dimensions 42 x 25 x 12 mm
Weight (incl. 10 m cable) 0.3 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67/IP69K
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-ABA-01
Assured switch-off distance S
ar
- - 23
mm
Operating distance for center offset m = 0
1)
- Switch-on distance - 6 -
- Assured switch-on distance S
ao
5- -
- Switching hysteresis 0.5 1.5 -
In combination with actuator CES-A-BBA on evaluation unit CES-A-ABA-01B
Assured switch-off distance S
ar
--32
mm
Operating distance for center offset m = 0
2)
- Switch-on distance - 15 -
- Assured switch-on distance S
ao
10 - -
- Switching hysteresis 0.5 2 -
Minimum distance s with lateral approach direction - 3 -
In combination with actuator CES-A-BDA on evaluation unit CES-A-ABA-01
Assured switch-off distance S
ar
- - 24
mm
Operating distance for center offset m = 0
3)
- Switch-on distance - 7 -
- Assured switch-on distance S
ao
6- -
- Switching hysteresis 0.5 1.5 -
Minimum distance s with lateral approach direction - 1 -
Installation in steel, non-flush/flush
Assured switch-off distance S
ar
- - 24
mm
Operating distance for center offset m = 0
- Switch-on distance - 4.4/3.6 -
- Assured switch-on distance S
ao
3.6/3 - -
- Switching hysteresis 0.4/0.3 1.2/1.0 -
Minimum distance s with lateral approach direction - 1 -
Installation in stainless steel, non-flush/flush
Assured switch-off distance S
ar
- - 24
mm
Operating distance for center offset m = 0
- Switch-on distance - 4/3.3 -
- Assured switch-on distance S
ao
3.3/2.7 - -
- Switching hysteresis 0.4/0.3 1.1/0.9 -
Minimum distance s with lateral approach direction - 1 -
In combination with actuator CES-A-BDA on evaluation unit CES-A-ABA-01B
Assured switch-off distance S
ar
--33
mm
Operating distance for center offset m = 0
3)
- Switch-on distance - 16 -
- Assured switch-on distance S
ao
11 - -
- Switching hysteresis 0.5 2 -
Minimum distance s with lateral approach direction - 4 -
Connection cable Hard-wired encapsulated connection cable, with crimped ferrules
PVC, 4.6 mm
PUR, 4.8 mm, suitable for drag chain
Cable length - - 25 m
1) These values apply to flush installation of the read head and the actuator in aluminum.
2) These values apply to non-flush installation of the read head and actuator.
3) These values apply to metal-free surrounding material. Other materials on request.
H11 H12 SH1
BN
WH
Screen
Read
head
Evaluation unit
CES-A-ABA...
Vedere la pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 41 42