Euchner CES-A-W5H-01 (Multicode) Manuale Utente Pagina 18

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 17
System Manual Safety System CES-A-W5H-01
18
System Status Table
Operating mode
Actuator/
Guard position
Safety outputs LA and LB
PLC
LED display
State
Output
OUT (status signal)
STATE (green)
OUT/ERROR (yellow)
OUT/ERROR (red)
Normal operation
closed on 1 Normal operation, door closed
open off 0 Normal operation, door open
State indication
X off 0
3 x +
Self-test after operating voltage is applied
Fault display
X off 0
Device-internal component failure or
excessively high interference (EMC) or short circuit/external power at
the LA/LB safety output
Key to symbols
N 0 Volt or not connected
1 24 Volt
0 0 Volt
LED is not lit
LED is lit
3 x +
LED flashes three times and then lights up continuously
X Any state
Vedere la pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 27 28

Commenti su questo manuale

Nessun commento