Euchner CES-AR-C01-CH-SA (Multicode) Manuale Utente Pagina 26

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 36
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 25
Operating Instructions Safety Switch CES-AR-C01-CH-SA
26
Switching distances
Operating distance for center offset m = 0
(only in combination with CES-A-BBA actuator)
Parameter Value Unit
min. typ. max.
Switch-on distance - 18 -
mm
Assured switch-on distance s
ao
1)
15 - -
Switching hysteresis
1)
1 3 -
Assured switch-off distance s
ar
- - 45
1) The values apply for surface installation of the actuator.
Typical operating distance
(only in combination with CES-A-BBA actuator)
Figure 7: Typical operating distance
X
25
15
20
10
5
20
25
30
5
10
15
-30
30
-30
25
20
15
10
5
Y
Z
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.